Magnetic Core Structural Features

  • Made of a single, constant-permeability magnetic material with permeability μ = 1500–4000.

 

Magnetic Core Performance Characteristics

  • Excellent capability to withstand DC components, suitable for current ranges of transformers (1.5–500 A).
  • High linearity, high accuracy, suitable for current transformer accuracy classes ranging from 0.5 to 0.1.
  • It exhibits good accuracy under both inductive and capacitive loads.
  • Good temperature stability
  • Miniaturization

 

Application areas

  • Current transformer for electricity meters with resistance to DC components
  • DC-component-resistant current transformers for power system measurement and control

 

Basic Material Parameters

Saturation Magnetic Induction (T) ≥1.4
Permeability μ 1500-4000
Coercive force Hc (A/m) ≤6.0
Residual magnetic flux density Br (T) ≤0.02
Density (g/cm³) 3 ) 7.3
Fill factor ≥0.82

 

DC Hysteresis Loop

 

Common size specifications

Product Grade

Core size

External dimensions

Accuracy class

Maximum DC Overcurrent Capability

SYH1MF 221706C

17×22×6

Φ15.6 × 23.9 × 8.3

Class 0.5–0.1

60A

SYH1MF 221707C

17×22×6.5

Φ15.6 × 23.9 × 8.5

Class 0.5–0.1

60A

SYH1MF 221706C-02

17×22×6

Φ15.6 × 23.9 × 8.3

Class 0.5–0.1

80A

SYH1MF 252006C

20/25 × 6

Φ18.7 × 26.7 × 8.1

Class 0.5–0.1

100A

SYH1MF 312005C

21×29.5×5

Φ19.2 × 32.0 × 6.7

Class 0.5–0.1

120A

SYH1MF 302506C

25×30×6

Φ22.0 × 33.0 × 9.0

Class 0.5–0.1

120A

Note: The dimensions listed above are for customers’ reference only; custom-made products can be provided according to specific customer dimensions and performance requirements.

AC-DC Current Transformer, Single Core (SYH1MF)


Magnetic Core Structural Features: • Composed of a single, constant-permeability magnetic material with permeability μ = 1500–4000. Magnetic Core Performance Features: • Excellent resistance to DC bias currents, suitable for current ranges of transformers (1.5–500 A). • High linearity and high accuracy; suitable for transformer accuracy classes ranging from 0.5 to 0.1. Delivers excellent accuracy under both inductive and capacitive loads. • Good temperature stability. • Compact size.
AC-DC Current Transformer, Single Core (SYH1MF)
AC-DC Current Transformer, Single Core (SYH1MF)
AC-DC Current Transformer, Single Core (SYH1MF)
+
  • AC-DC Current Transformer, Single Core (SYH1MF)
  • AC-DC Current Transformer, Single Core (SYH1MF)
  • AC-DC Current Transformer, Single Core (SYH1MF)

Phone: +86-10-62957217

Email: sales@bj-shouye.com

Email: jessica.wang@bj-shouye.com


Small magnetic core, big future.

NANO CORE, BIG FUTURE

Business license
中企跨境-全域组件 1.97 制作前进入CSS配置样式

在线客服添加返回顶部

右侧在线客服样式 1,2,3 4

图片alt标题设置: Beijing Shouye Magnetic Materials Technology Co., Ltd.

表单验证提示文本: Content cannot be empty!

循环体没有内容时: The materials are being organized—stay tuned!

CSS / JS 文件放置地